| Home | E-Submission | Sitemap | Editorial Office |  
top_img
Journal of Korean Neurosurgical Society 1993;22(4): 480-483.
A Simple Technique for Up-and-in Screw Placement on Fifth Lumbar Vertebra: Technical Notes.
Heung Sun Lee, Kyeong Seok Lee, Dong Keun Hyun, Park Jang Byun
1Department of Neurosurgery, Young Kwang General Hospital, Youngkwang, Korea.
2Department of Neurosurgery, College of Medicine, Soonchunhyang University, Seoul, Korea.
ABSTRACT
A simple technique for transpedicular screw fixation of L5 is presented. This percutaneous screwing allows up-and-in screw placement without excessive lateral stretching and lessens the length of incision.
Key Words: Transpedicle-screw fixation; Spine; Surgical technique
TOOLS
Full text via DOI  Full text via DOI
Download Citation  Download Citation
Share:      
METRICS
1,048
View
70
Download
Related article